美国ASCO8340系列4通电磁阀 在设定您可以启用或禁用的设备的所有输入的控制。 如果输入被禁止,他们被认为是始终关闭,无需跳线需要在端子板上。 使用跳线未使用的输入,如果你启用它们。 带DP控制激活(设置F07),清洗周期开始,并根据DP读数停止。

美国ASCO8340系列4通电磁阀  的详细介绍
美国ASCO8340系列4通电磁阀
B10 MANUAL ACTIVATION OF EVERY SINGLE OUTPUT
From the keyboard you can manually and individually activate every single output for an operation test.
Press key A to select the output you wish to activate. Press key C to activate the output.
C0 INPUTS ENABLE FROM KEYBOARD
In Set up you can enable or disable the control of all the inputs of the device.
If inputs are disabled, they are considered as always closed and no jumper is required on the terminal board.
Use a jumper for unused inputs if you enable them.
C1d DIFFERENTIAL PRESSURE DIGITAL CONTROL
With dP control active (Set F07), the cleaning cycle starts and stops according to the dP reading.
With dP reading under the STOP threshold the cleaning cycle stops and the display shows dP reading and letter P alternatively. The cleaning cycle stop
is at the end of the cycle.
With dP reading over the START threshold the cleaning cycle is able to start.
C3 DIFFERENTIAL PRESSURE READING BY INTERNAL TRANSDUCER (max 10 kPa)
C7d1 MAXIMUM dP ALARM WITH ALARMED OPEN CONTACT AND AUTOMATIC RESET
If the dP readout is above the threshold in Set up, the maximum dP alarm is activated. The display shows the alarm condition code E7 (see the alarm
description) or the dP readout and letter H alternatively, according to the model.
The corresponding alarm relay will signal its condition. The alarm is automatically reset when the dP readout is below the alarm threshold again.
The activation of this alarm is delayed by 20 seconds by default.
C8 ZERO dP READING ADJUSTMENT
In this set up code it is possible to adjust the zero reading of differential pressure. In this function the display shows the dP reading and, with plant stop
or air pipes not connected if the dP reading is not 0.00 kPa it is possible adjust it by key A and C.
C13_10 dP READING FULL RANGE 10 kPa
Maximun differential pressure measurable by the sequencer 10.00 kPa = 100.0 mbar = 1012 mmH2O.
With dP reading over 10 kPa the display shows 'E' instead of the numeric value of dP.
产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


产品搜索

联系我们
产品目录
Copyright@ 2003-2025  上海乾拓贸易有限公司版权所有        
 

沪公网安备 31011402005013号

点击这里给我发消息 点击这里给我发消息 点击这里给我发消息 点击这里给我发消息 点击这里给我发消息 点击这里给我发消息 点击这里给我发消息