a drop in suction force, or slow response time, stop operation and replace the filter.
1. Using a precision driver, remove the filter assembly (!2 or !4) from the main unit.
2. Turn the filter guide by hand and remove. 3. Replace the filter (!3 or !5)
描述SMC真空节流破坏阀 ,SMC真空节流破坏阀产品介绍
描述SMC真空节流破坏阀 ,SMC真空节流破坏阀产品介绍
的详细介绍
描述SMC真空节流破坏阀 ,SMC真空节流破坏阀产品介绍
上海乾拓贸易有限公司
企业QQ:2880626087
电话;
手机;(微信)
邮箱;@163.com
地址:上海市嘉定区江桥嘉涌路99弄6号713室
Pilot method Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note 3) Enclosure
Ambient and fluid temperature (°C) Max. operating frequency (Hz)
Operating pressure range (MPa)
24 VDC, 12 VDC ±10% of rated voltage∗ 0.4 0.15 Diode LED
Filter replacement instructions> If there are situations such as filter clogging,
a drop in suction force, or slow response time, stop operation and replace the filter.
1. Using a precision driver, remove the filter assembly (!2 or !4) from the main unit.
2. Turn the filter guide by hand and remove. 3. Replace the filter (!3 or !5)
and gently hand tighten the filter guide. At this time, check that there is no foreign matter on the O-ring of the filter assembly.
4. Return the filter assembly to the main unit. (Tightening torque: 0.12 N·m)
Spool valve assembly Spool valve assembly Body Adaptor plate Pilot adaptor Pilot valve assembly End cover Restrictor block assembly Note) Bottom cover Light cover
Resin/H-NBR Resin/H-NBR Zinc die-cast Resin Resin — Resin
A side (for release pressure switching) B side (for vacuum pressure switching) — White White — White
White Light blue Note) Set the operating torque of the restrictor of the restrictor block assembly to 0.3 N·m or less.
30 μm Light purple <Vacuum pressure side>, 5 pcs. included
30 μm Light purple <Vacuum pressure side>
Vacuum Release Valve with Restrictor
D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510
Manifold Valve Specifications
Note 1) Can be used with positive pressure to suit the application. Note
2) Please use with pilot X port pressure equal to or higher than the release port 1(P) pressure. Note
3) Impact resistance: No malfunction occurred when it is tested in the axial direction
and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz,
Test was performed at both energized and de-energized states in the axial direction
and at the right angles to the main valve and armature. (Values at the initial period)
Valve construction Fluid
1 μm White <Release pressure side>, 5 pcs. included
1 μm White <Release pressure side>
After tightening the plug (M-5P) with a tightening torque of 1 N·m, or manually tightening, use the tightening tool and tighten it by 1/4 turn.
!3!5 Filter (5 pcs. included)!2 !4 Filter assembly (with filter)
Adsorbing and Transferring System Circuit Example
Manual override (Manual operation)
3 position 3 port valve with restrictor Air 0.25 to 0.7 –100 kPa to 0.7 Note 1) 0.25 to 0.7 Note
2) –10 to 50 (No freezing) 3 Non-locking push type Push-turn locking slotted type Manual Slotted locking type
External pilot/Pilot valve individual exhaust Not required Unrestricted 150/30
Release pressure port 1(P) Vacuum pressure port 3/5(E) Pilot X port
∗ For the allowable voltage fluctuation for Z/T type (with power saving circuit),
please observe the following range because they have voltage drop due to internal circuit.
Z type 24 VDC: –7% to +10% 12 VDC: –4% to +10% T type 24 VDC: –5% to +10% 12 VDC: –6% to +10%
Coil rated voltage Allowable voltage fluctuation Power consumption
(W) Surge voltage suppressor Indicator type Standard With power saving circuit (Continuous duty type)